Print Back
Millennium Reinforced Perimeter Strip consists of reinforced EPDM membrane strip laminated with a 35 mil EPDM based pressure sensitive tape adhesive. The reinforced EPDM membrane is 6” (15.24 cm) wide mated to a 3” (7.62 cm) wide pressure sensitive tape adhesive.

Basic Use
Millennium Reinforced Perimeter Strip is designed for non-penetrating securement of the EPDM membrane in ballasted, fully adhered, and mechanically fastened roof systems.
Unit of Measure

Specifications

Surface Preparation

N/A All work surfaces should be clean, dry, and free of dirt, dust, debris, oils, un-adhered coatings, deteriorated membrane and other contaminants that may result in a surface that is not sound or is uneven.

Safety

N/A Prior to working with this or any product consult product label and Material Safety Data Sheet (MSDS) for necessary health and safety precautions.

Limitations

N/A
  • Not to be used without mechanical fasteners.
  • Not to be used with PVC membrane.
  • Not to be used with TPO membrane.
  • Talc dust, oil, ice, snow or wet conditions inhibit good adhesion to the pressure sensitive tape. Clean and dry surfaces a

Color

N/A Black

Packaging & Coverage

N/A Millennium Reinforced Perimeter Strip is available in the following size:

Width

N/A 6 "152 mm

Rolls/Case

N/A 2

Storage and Shelf Life

N/A Store material in original unopened packaging at temperatures between 40 °F-110 °F. Shelf life is 12 months when stored as recommended.

Applications

N/A
  1. Place the Millennium Reinforced Perimeter Strip horizontally or vertically in the angle change with the pre-applied tape in the horizontal position and facing up.
  2. Install seam fastening plates and screws, a maximum of 12” (30.48 cm) o.c. Use fastener placement markings on EPDM sheet as a guide.
  3. Clean portion of EPDM field membrane that will be adhered over Millennium Reinforced Perimeter Strip.
  4. Apply EPDM Primer on portion of EPDM field membrane that will be adhered to the Reinforced Perimeter Strip utilizing the supplied pad. Scrub the membrane in a circular motion.
  5. Allow the primer to dry to the touch (no material transfer), typically less than 20 minutes. Dry time will vary depending on ambient temperature and humidity.
  6. Once the primer is dry immediately install EPDM membrane. Remove release liner and set the EPDM membrane onto the Millennium Reinforced Perimeter Strip and press in by hand.
  7. Pull the membrane back to expose the un-adhered portion of the Millennium Reinforced Perimeter Strip.
  8. Install EPDM manufacturers recommended membrane bonding adhesive to the wall, membrane, and Reinforced Perimeter Strip.
  9. Once adhesive has dried roll the membrane in place for 100% adhesion.

Technical Data

N/A
Typical Physical Properties and Characteristics
  Typical Values Test Method
Base Polymer (Cover & Tape) EPDM FTIR
Color (Cover & Tape) Black Visual
Peel Strength 10 pli @ 70 ºF ASTM D413
Shear Strength 20 psi @ 70 ºF ASTM D816
Brittleness Temperature -50 ºF ASTM D2137

Benefits

N/A Extends membrane service life Improved safety Minimizes leak potential Saves time and labor

Note

N/A The foregoing information is published as general information only. The listed properties and performance characteristics are typical values and are not to be interpreted as manufacturing specifications.

Features

N/A Eliminates fastening through membrane Eliminates membrane bridging No torches or liquid adhesives required Quick and easy Installation

Length

N/A 100 '30.48 m